Welcome to BSES > About Us > BSES at a glance

BSES Yamuna Power Limited (BYPL)


BYPL distributes power to an area spread over 200 sq kms with a population density of 6989 per sq km. It's 14 lakh customers are spread over 14 districts across Central and East areas including Chandni Chowk, Daryaganj, Paharganj, Shankar Road, Patel Nagar, G T Road, Karkardooma, Krishna Nagar, Laxmi Nagar, Mayur Vihar, Yamuna Vihar, Nand Nagri and Karawal Nagar.

BSES Rajdhani Power Limited (BRPL)


BRPL distributes power to an area spread over 750 sq. km with a population density of 2665 per sq km. It's over 21 lakh customers are spread in 19 districts across South and West areas including Alaknanda, Khanpur, Vasant Kunj, Saket, Nehru Place, Nizamuddin, Sarita Vihar, Hauz Khas, R K Puram, Janakpuri, Najafgargh, Nangloi, Mundka, Punjabi Bagh, Tagore Garden, Vikas Puri, Palam and Dwarka.


System Augmentation and record AT&C loss reduction


Since taking over distribution, BSES’ singular mission has been to provide reliable and quality electricity supply.

BSES has invested over Rs 6600 crores on upgrading and augmenting the infrastructure which has resulted in a record reduction of AT&C losses.

From a high of 63.1 % AT&C losses in BYPL area in 2002 the losses have come down to 18.9%** in FY15, a reduction of 44%.

Similarly, in BRPL area AT&C losses have been reduced from 51.54% to 13.9%** in FY15, a record reduction of 38%

** provisional; pending true up

SN

Particular

UoM

BYPL

BRPL

BSES Delhi

(East & Central)

(South & West)

1

Area

sq. km

200

750

950

2

Customer Density
(As of Mar '15)

Cons /
 sq km

7249

2802

3738

3

Total Registered Customers
(As of Mar '15)

Million

1.4

2.1

3.55

4

Peak Demand  (YTM  FY 15)

MW

1496

2550

4046


The following operational statistics given an overall view of the strength of BSES distribution network as of March 2015

SN

ITEMS

2002-03

FY 15

BSES
% Growth

BRPL

BYPL

BSES

BRPL

BYPL

BSES

1

Grids (Nos)

63

40

103

77

51

128

28

2

Power Transformers  (Nos)

146

98

244

217

142

359

45

3

EHV Capacity (MVA) 

3036

1863

4899

4966

3004

7970

61

4

EHV Cable Length/Line Length Laid (KM)

674

363

1037

1125

755

1880

108

5

66 & 33 kV Feeders (Nos)

132

89

221

200

147

347

65

6

Shunt Capacitors (MVAr)

810

573

1383

1470

961

2431

68

7

Distribution Transformer (Nos)

4852

2657

7509

7056

3550

10606

34

8

Distribution Transformers Capacity (MVA)

2587

1704

4291

4241

2578

6819

51

9

11 kV Feeders (Nos)

733

476

1209

1147

738

1885

55

10

11 KV Cables laid (Kms)

1595

1303

2898

2180

1779

3959

37

11

11 KV Lines laid (Kms)

1566

145

1711

1783

249

2033

72

12

LT Feeders (Nos)

15219

10193

25412

21832

13447

35279

32

13

LT Lines laid (Kms)

5382

4589

9971

10445

5630

16075

23